Abstract
In the present communication, comparison between performance of photovoltaic module with and without duct has been carried out. Different input parameters (namely, ambient air temperature, solar radiation wind speed etc.) have been considered for HT, Delhi campus. Further, thermal modelling has been derived for the c-Si photovoltaic (PV) module alone and PV module with duct. Different parameters like outlet air temperature from duct and cell temperature have been calculated through MATLAB coding. Due to integration of duct, 3.89\% and 125.74\% increase in electrical output and equivalent thermal energy have been found in comparison to stand-alone PV module. © 2019 Elsevier Ltd. All rights reserved.
Figures & Tables (7)
  • Figure-0
    Fig. 1. Schematic diagram of photovoltaic module.
  • Figure-1
    Fig. 2. Schematic diagram of photovoltaic module with air duct.
  • Figure-2
    Fig. 4. Solar cell temperature and solar cell efficiency.
  • Figure-3
    Fig. 5. Electrical energy from PV module (Elpv) and PV module ... Expand
  • Figure-4
    Fig. 3. Total solar radiation, outlet air temperature from duct ... Expand
  • Figure-5
    Fig. 6. Overall or equivalent thermal energy from PV module ... Expand
  • Figure-6
    Fig. 7. Overall or equivalent thermal efficiency for PV module ... Expand