The results of MeV Kr+ ion-beam mixing of Au in amorphous metallic alloy Fe78B13Si9 at room temperature for various doses are presented. The mixing rate found experimentally does not correlate with prediction of current phenomenological models which consider the influence of ballistic and thermodynamic parameters of the mixing.